Model No.: GDVA-404
Production Capacity: 300 sets per month
Delivery Date: 15 working days once order ...
Means of Transport: Air
Packing: Standard wooden case
Standards: IEC60044-1, IEC60044-6, GB1...

This Current Transformer CT PT Test Set is performing excitation, ratio and phase error, polarity, secondary loop burden and coil resistance


2)Polarity test
3) Secondary burden test
4) Coil resistance test

 

 

 

Applications for Current Transformer  CT PT Test Set :
1) CT nameplate check
2) CT parameters check in work burden
3) CT transient parameters analysis
4) CT ratio and phase error calibration
5) PT routine test

 

 

 

III  Technical  Parameter for  Current Transformer  CT PT Test Set

 

 

ModelGDVA-404  Current Transformer  CT PT Test Set
Test standardsIEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
Power supplyAC220V±10%,50Hz/60Hz±10%
Power output0.1~125V (AC)
Current output0.001~5A(RMS)
Power output300VA
Maximum knee voltage measurement45kv
Current measurementRange:0~10A (automatically change range in 0.1/0.4/2/10A)           
Error <±0.1%+0.01%FS
Voltage measurementRange:0~200 V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
Turns ratio measurementRange :1~30000
1~2000 error<0.05%
2000~5000 error>0.1%
5000~30000 error<0.2%
Phase measurementerror:±2min,resolution:0.01min
Coil resistance measurementRange:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS
Maximum resolution:0.1mΩ
Temperature measurement   -50~100 Celsius degree, error<3 Celsius degree
CT Secondary burdenRange 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution 0.001ohm
PT Secondary burdenRange 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
PT ratio measurementRange :1~30000
1~5000 error<0.2%
5000~30000 error<0.5%
Saved data groups>1000groups
Work conditionTemperature:-10ºC~50ºC, moist:≤90%
Size485mm×356mm×183mm
Weight<15Kg

 

 

IV Related   Current Transformer  CT PT Test Set

GDVA-402    CT PT  Test Set

GDVA-405  Mutil-Function Current Transformer CT PT Test Set 

 


bigPhoto
 Ms. Sunny

Tel: 86-23-62984892
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Chongqing Gold Electric Equipment Co.,Ltd [China (Mainland)]


Business Type:Manufacturer
City: Chongqing
Province/State: Chongqing
Country/Region: China (Mainland)

You May Like:

Product (225)